Cardiac Pacemaker, Cardiac Resynchronization Therapy (CRT), Implantable Cardioverter-Defibrillator (ICD) - Peking Union Medical College Hospital
A cardiac pacemaker is an artificial "command center" that can replace the heart's pacemaker site, causing the heart to beat rhythmically. The cardiac pacemaker is a pulse generator composed of a battery and circuits, capable of delivering pulsed electrical currents at a fixed frequency at scheduled intervals; these currents are transmitted via pacing electrode leads to the atrial or ventricular muscle, stimulating local myocardial cells to become excited. The excitation spreads through intercellular conduction, resulting in contraction of the entire atrium and/or ventricle. The heart's electrical signals cause it to beat. When active, the heart beats faster; during sleep, the heart beats slower. If the cardiac electrical system is abnormal, the heart may beat very slowly or may even stop completely. The artificial cardiac pacemaker emits regular electrical pulses, enabling the heart to remain beating. Heart...
Published November 26, 2026 / Reviewed November 26, 2026
Plan your visit
Start your hospital treatment guide to review the steps before you contact or visit a hospital.
Information only. No diagnosis or treatment recommendation.

Image source: Peking Union Medical College Hospital · https://www.pumch.cn/Uploads/Picture/2017/12/08/u5a2a2938e8bf1.gif
A cardiac pacemaker is an artificial "command center" that can replace the heart's pacemaker site, causing the heart to beat rhythmically. The cardiac pacemaker is a pulse generator composed of a battery and circuits, capable of delivering pulsed electrical currents at a fixed frequency at scheduled intervals; these currents are transmitted via pacing electrode leads to the atrial or ventricular muscle, stimulating local myocardial cells to become excited. The excitation spreads through intercellular conduction, resulting in contraction of the entire atrium and/or ventricle. The heart's electrical signals cause it to beat. When active, the heart beats faster; during sleep, the heart beats slower. If the cardiac electrical system is abnormal, the heart may beat very slowly or may even stop completely. The artificial cardiac pacemaker emits regular electrical pulses, enabling the heart to remain beating. Heart...
Cardiac Pacemaker
Initially, the battery portion of the artificial cardiac pacemaker was placed externally on the body, with leads extending from outside the body through veins to the heart. They could only be used for a short period within a hospital. Later, Rune Elmquist manufactured an implantable pacemaker in 1958; a zinc-mercury cell was buried subcutaneously. In 1960, Swedish physician Oke Sennings implanted this type of pacemaker in a patient. The battery remained in use for 2---3 years before replacement. In the 20th century 80s, a microprocessor was added to the pacemaker. The patient only activated it when they felt the need for a pacemaker. Today's pacemakers are even more complex; they can adjust heart rate based on blood humidity. In 1988, a patient had a nuclear-powered pacemaker implanted. This pacemaker used trace amounts of plutonium and could remain functional for 20 years.
What Are the Functional Types of Cardiac Pacemakers?
(1) Atrial Demand (AAI) Mode: Electrodes are placed in the atrium. The pacemaker delivers pulses to pace the atrium according to a specified perimeter or frequency, and transmits the impulse down to the ventricle to maintain sequential contraction of the atrium and ventricle. If there is intrinsic atrial activity, the pacemaker can detect the intrinsic P wave, initiate inhibition, and reset the pulse delivery cycle to avoid atrial rhythm competition.
(2) Ventricular Demand (VVI) Mode: Electrodes are placed in the ventricle. The pacemaker delivers pulses to pace the ventricle according to a specified perimeter or frequency; if there is intrinsic cardiac beat, the pacemaker can detect the intrinsic QRS wave, initiate inhibition, and reset the pulse delivery cycle to avoid rhythm competition. However, this type of pacemaker only ensures ventricular pacing rhythm and cannot simultaneously maintain synchronization, sequence, and coordination of atrial and ventricular contraction, and is therefore non-physiologic.
(3) Dual-Chamber (DDD) Pacemaker: Electrodes are placed in both the atrium and ventricle. If the intrinsic heart rate is below the pacemaker's lower limit frequency, resulting in impaired ventricular conduction function, the pacemaker detects the P wave to trigger ventricular pacing (operating in VDD mode). If the intrinsic atrial (P) frequency is too slow but atrioventricular conduction function is intact, the pacemaker paces the atrium and transmits the impulse to the ventricle (operating in AAI mode). The logic of this dual-chamber pacemaker always maintains synchronized, sequential, and coordinated contraction of the atrium and ventricle. If only VDD mode is required, a single-lead VDD pacemaker can be used, which is much more convenient than placing two leads, one in the atrium and one in the ventricle.
(4) Rate-Adaptive (R) Pacemaker: The pacing frequency of this type of pacemaker can automatically adjust and adapt according to the body's demand for cardiac output (i.e., oxygen demand); as the pacing frequency increases, cardiac output increases correspondingly to meet the body's physiological needs. Most rate-adaptive pacemakers currently in use are motion-sensing types, and some are minute ventilation-sensing types. A VVI pacemaker with rate adaptation is called VVIR type; an AAI pacemaker with rate adaptation is called AAIR type; a DDD pacemaker with rate adaptation is called DDDR type. The above atrial demand pacemakers, dual-chamber pacemakers, and rate-adaptive pacemakers all belong to physiological pacemakers.
(5) Program control function of pacemaker: Refers to an implantable pacemaker, which can have its mode of operation and operating parameters altered externally using a program controller. After implantation of a pacemaker, a set of optimal mode of operation and operating parameters can be prescribed based on the individual patient's specific circumstances, enabling the pacemaker to achieve maximum efficacy while conserving costs and maintaining the longest service life; in some cases, certain malfunctions can also be eliminated non-invasively. Expansion of the program control function allows the pacemaker to store data, monitor heart rhythm, and perform electrophysiological studies.
Indications for pacemaker use
Severe bradycardia. Patients with cardiac arrest for 3 seconds or longer, or with heart rates frequently below 40 beats per minute, especially those experiencing blackouts before the eyes or sudden fainting, should undergo pacemaker implantation. This constitutes the primary and original therapeutic scope of pacemakers.
Weak cardiac contraction. If a disease damages the myocardium or alters its original morphology, it may prevent the myocardium from contracting forcefully. Decline in cardiac contractile function leads to insufficient cardiac pumping, preventing various body parts from receiving adequate fresh blood and resulting in symptoms such as dizziness, chest tightness, and fatigue. In cases such as congestive heart failure unresponsive to pharmacotherapy and severe hypertrophic obstructive cardiomyopathy, multiple pacemakers may be implanted in different portions of the heart to generate multiple electrical stimulation commands synchronously, thereby assisting myocardial contraction.
Cardiac arrest. Cardiac arrest lasting several minutes can be fatal; certain diseases may trigger cardiac arrest or life-threatening malignant ventricular arrhythmias (such as rapid ventricular tachycardia and ventricular fibrillation). Pacemakers with defibrillator functionality may be implanted to restore regular cardiac beating.
In certain comprehensive treatments for heart disease (carotid sinus hypersensitivity syndrome, vasovagal syncope, idiopathic Q-T prolongation syndrome, prevention of rapid atrial arrhythmias, etc.), the pacemaker remains an indispensable or sole treatment option.
Pacemaker implantation procedure
The pacemaker implantation surgery is performed by a cardiologist and is typically carried out under local anesthesia. The method involves inserting electrode leads through veins in the arm or below the clavicle, and under X-ray fluoroscopy, advancing them to the predetermined cardiac chamber pacing site, where they are secured and tested. The pacemaker connected to the electrode leads is then implanted in the chest, the skin is sutured, and the procedure is complete.
What should be considered prior to cardiac pacemaker implantation?
(1) Medical history: Assessing the patient's onset of illness and previous diagnosis and treatment course.
1) General data: Age, sex, height, weight, development, dietary habits, and nutritional status
2) Family history: Presence of patients with heart disease within the family.
3) Past medical history and medication history: Presence of other diseases and drug allergy history.
(2) Physical condition: Assessing the characteristics and type of the disease, function of major organs, etc., as well as the type of pacemaker required for the patient.
1) Cardiac and systemic symptoms: Such as the patient's heart rate, heart rhythm, body temperature, activity tolerance, and level of self-care ability.
2) Auxiliary examinations: Electrocardiogram, cardiac Doppler examination, complete blood count, and coagulation and bleeding times.
3) Psychological and social support status: Given the high cost of pacemakers, it is necessary to assess the degree of family support for the procedure, the patient's psychological state, and their level of understanding and mastery of postoperative rehabilitation knowledge.
Precautions in the short postoperative period:
(1)Absolute bed rest for 24 h within 2 days postoperatively, maintaining a supine position or low-elevation decubitus position; turning is prohibited. On the th day postoperatively, appropriate lateral positioning on the operative side may be adopted. Immobilization of the limb on the operative side is required for 1 weeks postoperatively, with enhanced monitoring of cardiac rhythm changes. During limb function exercises in the postoperative recovery period, the principle of gradual progression should be followed; avoid vigorous repetitive swinging movements of the affected limb, large-range abduction, elevation, loading of the affected shoulder, or jumping from heights. If shoulder muscle twitching occurs, it may indicate lead dislodgement, and immediate evaluation at a hospital is required.
(2)Early postoperatively, local dressings should be kept clean and dry; if dressings become wet or fall off, they should be replaced promptly. After suture removal, local skin should remain clean; tight undergarments should not be worn. If local redness, swelling, pain, or even skin ulceration occurs postoperatively, self-management at home is not advisable. If systemic symptoms such as fever are present concurrently, the possibility of infection should be considered, and prompt evaluation and treatment at a hospital are required.
Nursing care during the postoperative recovery period:
(1)Generally, symptoms such as dizziness and fatigue previously present in patients after pacemaker implantation will improve; however, if these symptoms persist postoperatively, particularly in patients with ventricular pacing, evaluation at a hospital is required to determine whether artificial pacemaker syndrome has developed. Once diagnosed, if symptoms are pronounced, replacement with an atrial-synchronized or atrioventricular sequential pacemaker is necessary.
(2)Whether medication should continue after pacemaker placement depends on the severity of the patient's underlying disease. A pacemaker can only address cardiac conduction issues; if baseline cardiac function is poor or other cardiac conditions are present, medication should still be continued according to clinical status. This effectively maintains cardiac function and reduces the impact of the pacemaker itself on cardiac function.
(3)Early limb function exercises postoperatively promote local blood circulation and facilitate wound healing. Mild incision pain may occur early, which is normal, and should be continued after discharge. Exercises should progress gradually without haste; gradually increase the range of arm elevation, chest expansion, or "wall-climbing"-like movements until the arm can be raised above the head to touch the contralateral earlobe. Early restoration of normal limb function is essential for improving the patient's postoperative quality of life.
(4)Generally, pacemaker operation tends to stabilize after patient discharge; however, many patients frequently worry that the pacemaker may suddenly fail or cease functioning. Therefore, providing necessary explanations is key to alleviating their psychological stress. Patients should be informed that the electricity in the battery cannot suddenly deplete but only gradually dissipates. Consequently, the heart will never suddenly stop beating. Nevertheless, occasional unexpected situations may occur: if a patient inadvertently enters a high-voltage electromagnetic field or unintentionally exceeds the safe distance between a handheld telephone and the pacemaker, the patient may experience some unusual systemic sensations. In severe cases, this may lead to arrhythmia. At such times, the patient need not panic; once the patient leaves the affected area, the pacemaker will quickly return to normal operation. In certain unexpected circumstances, if the pacemaker suffers severe impact or excessive limb loading, it may malfunction or even experience lead disconnection. The patient may then experience discomfort to varying degrees. In severe cases of pacemaker dependence, symptoms such as presyncope and dizziness may recur, and self-monitoring of pulse will reveal a heart rate slowed below normal. At this point, activity should be stopped immediately, the limb on the operative side immobilized, and the pacemaker card (containing important information such as implantation time and pacemaker type) carried; the patient should then proceed promptly to a hospital for physician evaluation.
Monitoring of pacemaker function:
(1)Patients should be taught self-pulse monitoring postoperatively, as checking the pulse is a simple and effective method for monitoring pacemaker operation. When monitoring the pulse, ensure that it is performed daily under the same physical condition, such as upon waking each morning or after sitting quietly for 15 mim.
(2) In the early phase following pacemaker implantation, the pacing threshold is often unstable and requires timely adjustment. Therefore, regular visits to the hospital are necessary; generally, 1 visits within 3-6 months postoperatively, and then 1 visits annually thereafter. There are many factors that cause elevated thresholds; in addition to those related to electrode position, factors such as insufficient sleep, a full meal, antiarrhythmic drugs, and hypertension may also have an impact. Therefore, postoperative patients should maintain a positive emotional state, ensure a regular lifestyle and daily routine, and avoid all possible adverse factors.
Cardiac Resynchronization Therapy (CRT cardiac resynchronization therapy):
Cardiac resynchronization therapy is the treatment of patients with heart failure who exhibit ventricular contraction asynchrony through biventricular pacing. Patients with severe heart failure frequently experience ventricular contraction asynchrony; CRT adds left ventricular pacing to conventional bicaval pacing. The left ventricular pacing electrode enters the left posterior and lateral branches of the coronary vein via the ostium of the coronary sinus in the right atrium, thereby pacing the left ventricle, while simultaneously pacing the right ventricle. Multisite pacing restores ventricular synchronous contraction and reduces mitral regurgitation. For patients with heart failure accompanied by ventricular dyssynchrony, this treatment can improve cardiac function, enhance exercise tolerance, and improve quality of life, while also demonstrating a role in reversing left ventricular remodeling. Among patients with systolic dysfunction heart failure, patients with wide QRS complexes frequently have intraventricular or interventricular conduction abnormalities; during ventricular contraction, intraventricular or interventricular dyssynchrony occurs. Some patients with narrow QRS complexes may also experience dyssynchrony. Ventricular dyssynchrony causes the heart to lose co-orientated contraction: septal contraction occurs earlier, free wall contraction of the left ventricle is delayed, diastolic filling time is shortened, end-diastolic left ventricular pressure increases, ejection fraction declines, and cardiac output decreases. Progressive left ventricular enlargement and decreased contractility cause dilation of the mitral annulus, resulting in mitral regurgitation. Dyssynchronous contraction of the mitral papillae and surrounding myocardium further exacerbates mitral regurgitation. Ventricular dyssynchrony that develops after heart failure and these two conditions are mutually causal, forming a vicious cycle.
The concept of biventricular synchronous pacing was first proposed in 1983 by De Teresa at the Seventh Global Pacemaker Symposium. In 1998, Daubert implanted a left ventricular pacing electrode via the coronary vein, making biventricular synchronous pacing a reality.
In the European Society of Cardiology guideline for the treatment of chronic heart failure published in 2005 year, CRT is recommended as a Class I indication for the treatment of heart failure in patients. The indications are as follows: QRS>=120ms, left ventricular ejection fraction EF<=35%, NYHA class III-IV heart failure, and patients who do not respond to adequate medical therapy.
In the ACC/AHA guideline for the diagnosis and treatment of chronic heart failure in adults published in 2005 year, CRT is also a Class I indication for the treatment of patients. The indications are as follows: cardiac resynchronization therapy in patients with LVEF<=35% on optimal therapy, NYHA class III-IV cardiac dysfunction, and sinus rhythm (currently defined as QRS>0.12ms), unless there is a contraindication.
CRT can improve patients' cardiac function; however, during CRT treatment, 20-30% of patients still do not respond to CRT treatment, meaning that the clinical symptoms of these patients have not improved as a result of receiving CRT treatment. Given the technical requirements for implantation and healthcare costs, how to select appropriate patients so that more patients truly benefit from CRT treatment has become a focus of research.
Implantable Cardioverter-Defibrillator (ICD)
As is well known, approximately half of deaths in patients with heart disease are sudden cardiac deaths (i.e., sudden death). The most common cause of sudden cardiac death is severe ventricular arrhythmias, such as ventricular fibrillation and ventricular tachycardia. These severe arrhythmias often occur without warning prior to onset, and medications cannot fully prevent their occurrence. These arrhythmias must be terminated immediately when they occur; however, even within a hospital, treatment may sometimes be delayed. Because during ventricular fibrillation, the heart is actually unable to eject blood, and loss of cerebral blood flow for more than 6 seconds results in loss of consciousness. If the heart ceases to eject blood for more than 5 minutes, the chance of successful resuscitation is less than 20%. An ICD is a device used to terminate these severe arrhythmias at any time, and numerous studies have shown that ICD implantation is much more effective than pharmacological treatment. The appearance of an ICD is similar to that of a pacemaker, and the implantation site is also essentially the same, but an ICD is larger than a conventional pacemaker. Typically, an ICD has only one lead (implanted in the right ventricle). An ICD can detect and determine at any time the type of severe ventricular arrhythmia occurring in a patient and provide different interventions, thereby achieving the goal of terminating the arrhythmia and saving the patient's life.